Model STXD direct drive fans are designed to exhaust air in high static pressure applications to 1-1/2”. The aluminum exterior provides an attractive appearance. The non-overloading backward inclined wheel with its higher static pressure capability makes this unit suitable for either ducted or non-ducted applications. Its roof or wall mounting permits location near the area to be ventilated, allowing short duct runs and more efficient operation. Direct drive units use smaller diameter wheels with lower rpm's, resulting in low sound levels and quiet operation. They have no belts or fan bearings to maintain or adjust and consequently require very little maintenance.
Isolation of the motor from the air stream and the high velocity vertical (roof) or horizontal (wall) air discharge make the Model STXD ideally suited for the removal of dirty, contaminated and/or high temperature air from processes and buildings. Typical applications include restaurant hoods and similar kitchen exhaust ventilation, fume and smoke removal, laboratory fume hood exhaust and chemical process exhaust.
FEATURES
Temperature rating up to 300 degrees F
Spun aluminum exterior
Direct drive units have low sound levels and quiet operation
Curved non-overloading backward inclined wheel for efficiency at higher static pressures
Roof or sidewall mounting options
AMCA tested
Miami-Dade NOA, Florida Product Approval and Texas Department of Insurance Licensing available upon request
- Model No.:
- STXD08HM1AS
- Voltage:
- 115
- Warehouse:
- Florida
- Made In U.S.A.:
- Yes
- Type:
- Exhaust Fans
- Blade Material:
- Aluminum
- Blade Size (Inches):
- 8
- CFM High:
- 612
- Hertz:
- 60
- Drive Type:
- Direct
- Horsepower:
- 1/25
- Limited Warranty:
- 1 Year Limited Motor
- RPM High:
- 1150
- Phase:
- 1
- Speed(s):
- Variable
- Weight lbs.:
- 82
-
Notice: Manufacturer's products features and specifications are subject to change without notice.
-
California Residents: WARNING- This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
QUESTIONS & ANSWERS
Ask a Question-
I assume this unit con be used for exterior roof applications, but how does rainwater that enters the top of the fan "exit the unit" without getting into the building? The section available is not clear. Please asvise
Yes, this is a rooftop mounted exhaust fan. These type upblast fans use a butterfly type damper and rain gutter system that does not allow rain water to enter the building through the fan.