AirFlo-SF Exhaust Fan w/ Shutters 12 inch 1683 CFM 2 Speed SF12E2
Highly Recommended Items:
Quantity | Unit Price | You Save |
---|---|---|
6-9 | 3% | |
10+ | 5% |
General information:
standard wall fans follow a tradition of quality in design, materials and construction. all our standard wall fans are developed to be efficient and economically priced.
Features
all fans use a totally enclosed, ball bearing motor with thermal overload protection.
the motor mount is manufactured with heavy welded rods and has a powder coated finish.
the fan blades are well-balanced, heavy gauge aluminum.
the rugged steel welded box housing has durable powder coated finish.
aluminum shutters are supported by long life nylon bushings (30" and 36" have pvc shutters).
all fans are shipped completely assembled.
*note: the motor full load amperage ratings are meant to be used as a general guideline only. the ratings are from the primary motor supplier. these amperage ratings may vary slightly if a different motor supplier is used. it is also possible that a motor manufacture may modify / improve / update a motor in which the amperage rating will change slightly.
Dimensions:
a = 17 1/4"
b = 14"
c = 6"
d (center to center) = 16"
e = 14 3/4"
n = 3
- Model No.:
- SF12E2
- Voltage:
- 115
- Warehouse:
- New York
- Type:
- Exhaust Fans
- Amps:
- 3.4
- Blade Material:
- Aluminum
- Blade Size (Inches):
- 12
- No. of Blades:
- 3
- CFM Low:
- 1144
- CFM High:
- 1683
- Construction:
- Steel
- Decibels (dBA):
- @ 5 ft = 64
- Dimension Inches:
- Width: 17 1/4" Depth: 14" Height: 17 1/4"
- Hertz:
- 60
- Drive Type:
- Direct
- Horsepower:
- 1/4
- Limited Warranty:
- 1 Year
- Motor Type:
- TE
- RPM High:
- 1725/1140
- Phase:
- 1
- Speed(s):
- 2
- Weight lbs.:
- 32
-
Notice: Manufacturer's products features and specifications are subject to change without notice.
-
California Residents: WARNING- This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
QUESTIONS & ANSWERS
Ask a Question-
I'm installing through a 6" in. thick pre-cast concrete wall. How big of a hole do I have to cut into the concrete wall for proper ventilation?
This fan will need a 15” square rough-in opening.
-
Will this fan fit through studs that are 16” on center? Do you think it adequate to use for a 3 car garage for air movement in 95 degree heat?
The holes for mounting this unit are 16" (center to center). This fan will exchange the air in a typical 3 car garage approx. once every 6 minutes. This should be adequate, unless more air exchanges is required.