AirFlo Explosion Proof Filtered Exhaust Fan 16 inch 2000 CFM Direct Drive 3 Phase NCFE16-A-3-E
Highly Recommended Items:
Quantity | Unit Price | You Save |
---|---|---|
3-5 | 4% | |
6+ | 7% |
NOTE: HAZARDOUS LOCATION FANS ARE SPECIAL NON-STOCK ITEMS AND CANNOT BE RETURNED OR CANCELLED.
Excellent for use where filtered exhaust air is required. Efficiently supplies clean, filtered air for OEM machinery and equipment markets such as pressurizing electrical cabinets.This fans is also an economical choice for small unducted paint spray booths.
MOTOR CLASSIFICATION
Class 1, Division 1, Group D
Class 2, Division 2, Group F & G
FEATURES
Rugged spark-resistant cast aluminum propellers are standard
Standard OSHA style propeller guard
Removable filter box section
Disposable 2" filters are high capacity, pleated type that meet MERV 8 Rating
- Model No.:
- NCFE16 -A -3 -E
- Voltage:
- 230 / 460
- Warehouse:
- Ohio
- Made In U.S.A.:
- Yes
- Type:
- Explosion Proof Fans
- Amps:
- 230V: 1.34
460V: .67
- Blade Material:
- Cast Aluminum
- Blade Size (Inches):
- 16
- CFM High:
- 2000
- Dimension Inches:
- Width: 22.75" Depth: 24" Height: 20.25"
- Hertz:
- 60
- Drive Type:
- Direct
- Horsepower:
- 1/4
- Limited Warranty:
- 1 Year Limited
- Motor Type:
- Explosion Proof
- RPM High:
- 1725
- Phase:
- 3
- Speed(s):
- 1
- Weight lbs.:
- 160
-
Notice: Manufacturer's products features and specifications are subject to change without notice.
-
California Residents: WARNING- This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
QUESTIONS & ANSWERS
Ask a Question-
Can we use a Merv 10-11 filter in place of the 8 without overtaxing the motor?
Hello.
Yes you can use a Merv 10 or 11 filter on this fan without overtaxing the motor.
A Merv 11 filter adds approximately 0.27" of static pressure. This fan can handler up to 0.375" of static.